STARLIGHT is a modern company of professional design and manufacturer

ANSI 1.2kV 1400A–3150A High-Current Transformer Bushings

High-current ANSI 1.2 kV transformer bushing series for 1400 A to 3150 A, with 4-hole, 6-hole and high-hole-count terminal pad variants.

Product Details

This high-current ANSI 1.2 kV transformer bushing family covers ratings from 1400 A to 3150 A. The catalog lists 4-hole, 6-hole and higher-hole-count terminal pad variants with metric conductor threads from M36×2.0 to M48×2.0. All source dimensions, creepage values and reference codes are grouped below for direct model comparison. Source-table discrepancies are retained as notes rather than silently corrected.

Series Overview

  • Voltage range: 1.2 kV
  • Current range: 1400–3150 A
  • Configurations: 4-hole / 6-hole / high-hole-count terminal pads
  • Available catalog variants: 11

Available Models and Technical Parameters

Model H h1 h2 Md B Mounting Holes t Creepage Code Note
ANSI-1.2KV-1400A-4-HOLE 308 109 80 M36×2.0 101.6 4ר14.3 12.7 50 12XD.MBTG.094
ANSI-1.2KV-1600A-4-HOLE 308 109 80 M38×2.0 101.6 4ר14.3 12.7 50 12XD.401.018
ANSI-1.2KV-1600A-6-HOLE 354 109 80 M38×2.0 101.6 6ר14.3 12.7 50 12XD.401.017-3
ANSI-1.2KV-2000A-4-HOLE 308 109 80 M42×2.0 101.6 4ר14.3 12.7 50 12XD.401.016
ANSI-1.2KV-2000A-6-HOLE 354 109 80 M42×2.0 101.6 6ר14.3 12.7 50 12XD.MBTG.100
ANSI-1.2KV-2000A-10-HOLE 450 109 80 M42×2.0 101.6 10ר14.3 12.7 50 12XD.MBTG.076
ANSI-1.2KV-2500A-4-HOLE 308 109 80 M45×2.0 101.6 4ר14.3 12.7 50 12XD.401.017
ANSI-1.2KV-2500A-6-HOLE 308 109 80 M45×2.0 101.6 6ר14.3 12.7 50 12XD.401.017-4
ANSI-1.2KV-3150A-4-HOLE 308 109 80 M48×2.0 101.6 4ר14.3 12.7 50 12XD.401.019
ANSI-1.2KV-3150A-6-HOLE 354 109 80 M48×2.0 101.6 6ר14.3 12.7 50 12XD.401.019-6K
ANSI-1.2KV-3150A-10-HOLE 486.5 109 80 M48×2.0 101.6 12ר14.3 12.7 50 12XD.401.019-A Model designation says 10-hole, while the source dimension table lists 12ר14.3 mounting holes.
ANSI 1.2kV 1400A–3150A High-Current Transformer Bushings – Mechanical dimensions drawing
Mechanical dimensions drawing for ANSI 1.2kV 1400A–3150A High-Current Transformer Bushings.

Dimensions are in millimeters unless otherwise indicated. Thread designations and reference codes are reproduced from the source catalog. A dash indicates that no value is listed in the source table.

Voltage Class1.2kV
Current Rating1400A
StandardANSI / IEEE / IEC as applicable

Suitable for pad-mount transformers, distribution transformers and ring-main units. Final selection should follow project standards and cable dimensions.

Inquiry